11921 Slauson Ave. Santa Fe Springs, CA. 90670 (800) 227-4116 FAX (888) 771-7713
8. Put 25-pound weight
on threshold plate (FIG.
64-1). The warning alarm
and beacon lights should
turn on. If alarm and bea-
con lights don’t come on,
alternately turn left side
and right side adjustment
screws clockwise until
alarm & beacon lights are
turned on.
25 POUND WEIGHT ON THRESHOLD PLATE
FIG. 64-1
9. Move 25-pound weight to
several different places
across threshold plate
(FIG. 64-1). Alarm and
beacon lights should turn
on with load anywhere on
threshold plate.
THRESHOLD (MAT) SWITCH ADJUSTMENT - Continued