PATENTS PENDING
2. To open the release valve (FIG. 32-1),
turn the backup pump handle counter-
clockwise.
USING BACKUP PUMP TO UNFOLD
(LIFT WITH LH PUMP)
FIG. 32-1
LIFT RESTING ON
LATCHES
FIG. 32-2
NOTE: When the power switch is
turned on, you have 5 minutes
to do the adjustment before
the controller repressurizes
hydraulic system and stows
the Lift.
RELEASE
VALVE
BACKUP PUMP
HANDLE
NOTE: The STOW switch adjustment
screw is always on the same
side of the Lift as the pump
cover (FIG. 32-3).
RH PUMP
LH PUMP
ADJUSTMENT
SCREW
LOCATION OF ADJUSTMENT SCREW
FIG. 32-3
CAUTION
!
To prevent possible injury, stay clear of
the Lift when the controller repressur-
izes the hydraulic system. The system
will repressurize every 5 minutes after
the Lift is turned ON. If necessary, turn
the Lift OFF and then ON again to con-
tinue the adjustment.
STOW SWITCH ADJUSTMENT - Continued